Pagina 1 - Air Conditioner

BACnet GatewayMIM-B17Air Conditionerinstallation manualDB98-32390A(3)Eimagine the possibilitiesThank you for purchasing this Samsung product. MIM-B17_

Pagina 2 - Safety Precautions

E-10Compatible DevicesNo Devices Model Note1Indoor UnitOutdoor UnitAll System indoor/outdoor unitssuch as: DVM, DVM PLUS, DVM PLUS II, DVM PLUS III,

Pagina 3 - Contents

E-11Compatible DevicesDevices Max. NoteIndoor Unit 256 Tracking error occurs if exceededCentralized Controller16 Must not exceed 16 unitsInterface mod

Pagina 4 - Checks before installation

E-12Installation plateInstalling the BACnet Gateway 1Separate the installation plate on the rear side of BACnet Gateway.2 Fix the installation plate o

Pagina 5 - Accessories

E-13Assistant holewiring grooveInstalling the BACnet Gateway 4 Fix the installation plate and BACnet Gateway using 2 screws. Depending on the instal

Pagina 6 - Viewing the Parts

E-14Cable tieLAN cableConnect communication cableAdapterInstalling the BACnet Gateway (Continued)Connecting Centralized Controller1Unfasten the 2 scr

Pagina 7

E-15Cable tieLAN cableConnect communication cableAdapterInstalling the BACnet Gateway (Continued)Connecting Interface Module 1Unfasten the 2 screws o

Pagina 8 - Product Dimensions

E-16Cable tieLAN cableConnect communication cableAdapterConnecting SIM/PIM1Unfasten the 2 screws on the bottom of the BACnet Gateway front cover. Hol

Pagina 9 - System Architecture

E-17Address barSetting the BACnet GatewayBACnet Gateway Connection and Login1Click internet explorer icon( ) twice on your computer.2 When internet ex

Pagina 10 - Compatible Devices

E-18Setting the BACnet Gateway (Continued)4 Click [Run] button and continue installation. After installation, access to BACnet Gateway again. Silver

Pagina 11

E-19Setting the BACnet Gateway (Continued)55Enter ID and password when BACnet Gateway main web page appears, Then click [LOGIN]. If you click [Connect

Pagina 12 - Gateway

E-2 Safety Precautions Read carefully this installation manual before installation and check if the BACnet Gateway is installed correctly after i

Pagina 13 - Assistant hole

E-20Setting the BACnet Gateway (Continued)6 If you login successfully, 'Control and Monitoring' screen will appear. Click [System Setting]➔[

Pagina 14

E-21Setting the BACnet Gateway (Continued)7 If you access BACnet Gateway, 'Device Configuration' screen will appear initially.  If you cl

Pagina 15 - Connecting Interface Module

E-22Reading EHP Watt-hour MeterSetting and checking watt-hour meter1Click [System and Checking Watt-hour meter].  You can change settings on watt-ho

Pagina 16 - Connecting SIM/PIM

E-23Reading EHP Watt-hour MeterMonthly baseline setting1Click [System and Checking Watt-hour meter]. 2 Click [Edit] from the ‘Monthly baseline setting

Pagina 17 - Setting the BACnet Gateway

E-24Reading EHP Watt-hour Meter (Continued)Period setting1Click [System and Checking Watt-hour meter]. 2 Click [Edit] from the ‘Period setting’ screen

Pagina 18

E-25Reading EHP Watt-hour Meter (Continued)Channel setting by indoor unit1Click [Channel setting by indoor unit].2 Click [Edit] from the ‘Channel sett

Pagina 19

E-265Check the SIM/PIM interface module channel (Watt-hour meter) information of indoor/outdoor unit.  You can set the channel when SIM/PIM interfac

Pagina 20

E-27192.168.0.10006:12:13(AM)MAIN MENU1.IP ConfigAre you sure?YES:Set, NO:Menu1Press [Menu], [], [] or [Set] from the screen where IP and current ti

Pagina 21

E-28System SettingsBACnet Gateway network information You can set and check information about BACnet Gateway installation and operation. 1Click [Syst

Pagina 22 - Reading EHP Watt-hour Meter

E-29System Settings5When the pop-up window appears, click [OK]. 6If you click [OK], current internet explorer will be closed. Then you may run the web

Pagina 23

E-3 Contents Safety PrecautionS ... 2 Before inStalling the Bacnet gateway ...

Pagina 24 - Period setting

E-30System Settings (Continued)System time1Click [System Settings].2 Click [Edit] from the 'System time' section.3 Enter system time when te

Pagina 25

E-31System Settings (Continued)Selecting the language1Click [System Settings].2 Click [Edit] from the 'Select language' section.3 Select a l

Pagina 26

E-32System Settings (Continued)Selecting the contact point control pattern1Click [System Settings].2 Click [Edit] from the 'Select the contact po

Pagina 27 - System Setting Initialization

E-33System Settings (Continued)5 When the pop-up window appears, click [OK].  When message with “Reading data from DMS. Please wait” appears savi

Pagina 28 - System Settings

E-34System Settings (Continued)PatternControlPattern1▶ No external input (Factory default setting)When you input contact control signal in port 1,

Pagina 29

E-35System Settings (Continued) Pattern 2 (May be used for connection with a fire sensor)CH1CH2BACnet GatewayCH1CH2BACnet Gateway CH1CH2BACnet Gatew

Pagina 30 - System Settings (Continued)

E-36BACnet gateway information1Click [System Settings].2 You can check the basic BACnet gateway information from 'BACnet gateway information&apos

Pagina 31

E-37  What is tracking?Tracking is an operation that finds devices connected to BACnet Gateway. Through tracking operation, devices will be recogn

Pagina 32

E-38Tracking (Continued)Setting communication mode for each channel1Click [Device Configuration].2 Click [Edit] from the 'Communication mode by c

Pagina 33

E-39Tracking (Continued)3When each channel is enabled, check the communication mode you want to set for each channel.  You cannot change the commun

Pagina 34

E-4Checks before installation1BACnet Gateway IP A public IP is needed to access the BACnet Gateway over the internet. (One public IP is needed for e

Pagina 35

E-40Tracking (Continued)DVM Tracking1Click [Device Configuration].2 Click [DVM Tracking].12MIM-B17_BACnet Gateway_IM_E 32390-3.indd 40 2011-04-04

Pagina 36

E-41Tracking (Continued)3Enter administrator’s password.4Click [OK].5When tracking information window pops up, check it and click [OK] to continue.

Pagina 37 - Tracking

E-42Tracking (Continued)7Message will appear to alert that tracking is completed. Select the zone initializing mode and click [OK].  No initializa

Pagina 38 - Tracking (Continued)

E-43Disconnect all devices1Click [Device Configuration].2Click [Disconnect all devices].3Enter administrator’s password.4Click [OK].Device Configurati

Pagina 39

E-44Device Configuration (Continued)5When the information window pops up, you must check the information and click [OK] to continue.6When message with

Pagina 40

E-45Device Configuration (Continued)1From the list of devices searched by tracking, click [Edit] in the bottom of the list.  [Edit] will be changed

Pagina 41

E-46Device Configuration (Continued)2Enter the name of the devices when the text box enables.  You cannot use special characters within the device na

Pagina 42

E-47Device Configuration (Continued)1Click one of the Object ID from 'Object ID' column. Detail information of the selected device will be d

Pagina 43 - Device Configuration

E-48Device Configuration (Continued)2Analog data of the selected device will be displayed in Analog data.  Object ID: Displays ID of the correspondi

Pagina 44

E-49Device Configuration (Continued)6Binary data of the selected device will be displayed in Binary data.  Object ID: Displays ID of the correspond

Pagina 45 - Renaming the devices

E-5ItemBACnet Gateway Quantity 1ShapeAdapter Power cable M4x16 Screw11 6User’s manualInstallation manualCable tie1 1 1Make sure you have each item. Su

Pagina 46

E-5010Multi-state Data of the selected device will be displayed in Multi-state data.  Object ID: Displays ID of the corresponding object.  Type:

Pagina 47 - Checking device information

E-51BACnet Protocol Implementation Conformance StatementDate: May 24. 2010 Vendor Name: SAMSUNG Electronics CO., Ltd.

Pagina 48

E-52BACnet Protocol Implementation Conformance Statement (Continued)SUPPORTED BIBBSBIBB NAMESUPPORTED REMARKSAlarm and Event ManagementAE-N-A Alarm&a

Pagina 49

E-53BACnet Protocol Implementation Conformance Statement (Continued)SUPPORTED BIBBSBIBB NAMESUPPORTED REMARKSDevice and Network ManagementDM-R-A Resta

Pagina 50

E-54BACnet Protocol Implementation Conformance Statement (Continued)Data Link Layer Options: BACnet IP, (Annex J)  BACnet IP, (Annex J), Foreign Dev

Pagina 51

E-55Standard Object Types SupportedObject Type SupportDescriptionAnalog Input[Indoor temperature], [The power value after the basic date], [The numb

Pagina 52

E-56DeviceFollowing table shows regulation of device ID and they are created automatically.Refer to BACnet point ListDNET (Gateway number)Centralized

Pagina 53 - Multi-state Value

E-57Indoor UnitSingle indoor unit has following point list. Instance NumberObjectObject TypeObject NameUnit Status value InactiveActiveText-1 Text-2 T

Pagina 54

E-58BACnet Point List (Continued)Single AHU unit has following point list.Instance NumberObjectObject TypeObject NameUnit Status value InactiveActiveT

Pagina 55

E-59BACnet Point ListSingle ERV unit has following point list.Instance NumberObjectObject TypeObject Name Status value1 SIM error code AI SIM_Error_Co

Pagina 56 - 9 417 32

E-6BACnet Gateway ExteriorLCD Display Shows current time and IP address. Various messages will be displayed depending on button input.LCD operation bu

Pagina 57 - BACnet Point List

E-60 You may use ALL_OFF command to turn on all the indoor units but it is not recommended.  If communication error occurs on devices such as S

Pagina 58 - BACnet Point List (Continued)

E-61Other InformationObject setting when there is general errorIf any air conditioner related error occurs, the property will be set as below.1. The R

Pagina 59

E-62 MemoMIM-B17_BACnet Gateway_IM_E 32390-3.indd 62 2011-04-04 오후 3:44:31

Pagina 60

E-63 MemoMIM-B17_BACnet Gateway_IM_E 32390-3.indd 63 2011-04-04 오후 3:44:31

Pagina 61 - Other Information

MIM-B17_BACnet Gateway_IM_E 32390-3.indd 64 2011-04-04 오후 3:44:31

Pagina 62

E-7Name DescriptionDI Terminal1 Digital Input connection terminal, Channel1~Channel5DI Terminal2 Digital Input connection terminal, Channel6~Channel10

Pagina 63

E-8 24025564.80(Unit : mm)Display Board40-pin Cable20-pin CableMain BoardSub BoardBACnet Gateway InteriorMain PartsViewing the Parts (Continued)Note

Pagina 64

E-9  Connecting centralized controller and BACnet Gateway ( type) - You can control up to 16 centralized controllers and 256 indoor units using B

Commenti su questo manuale

Nessun commento

Hama Equipment cleansing kit user manuals

The list of Hama Equipment cleansing kit products contains 7 user manuals for 7 models. All pdf user’s guides are available for download or viewing online.

Click on an alphabet below to scroll to the full list of models starting with that letter

Models Document Type
00005934
Datasheet   Hama Cleaning Set Profi, 1 pages
00056593
Manual   Hama 00056593 equipment cleansing kit, 8 pages
49642
Datasheet   Hama 49642, 1 pages
49645
Datasheet   Hama 49645, 1 pages
73011538
Datasheet   Hama 73011538 equipment cleansing kit, 1 pages
73049647
Datasheet   Hama 73049647 equipment cleansing kit, 1 pages
73083746
Datasheet   Hama 73083746 equipment cleansing kit, 1 pages