Troubleshooting
The following table shows useful technical information for diagnosing and making error correction for various troubles which
may occur in the system. Before contacting your local installers, read this page carefully and implement visual inspections of
the whole system.
Possible causes Actions
Heating or cooling performance are not good
• Check the temperature adjustment in the controller
• Check if the water is filled in the system fully
• Check the water flow rate
Loud noise from water pump
• Check air purge valve (Make it open and close)
• Check if the water is filled in the system fully
• Check if strainer is full of foreign materials
System does not work even power source does not
have problem
• Check if wiring connections are installed well
• Check if water flow rate is low (system will not work in condition
of below 16 LPM)
Solar pump is not working
• Check TB-B and wire connections
Remote controller cannot be set
• Check if it has the mode of master or slave
• If there are 2 controllers, either one shall have slave mode.
• Always make sure to turn off the system before implementing the visual checking or disassemble for detail
checks.
CAUTION
• Incorrect handling of thermostat, safety valve or other valves may lead to tank rupture. When servicing the unit
follow instructions carefully:
- Always turn off main power supply when water supply is being shut off.
- Test the free operation of the safety valve regularly by opening the valve ensuring the water flows freely.
- Electrical connection and all servicing of the electrical components should only be carried out by an
authorized electrician.
- Fitting and all servicing of plumbing fixtures should only be carried out by an authorized installer.
- When replacing the thermostat, safety valve or any other valve or part supplied with this unit, use only
approved parts of the same specification.
WARNING
Error codes
If the unit has some problems and does not work normally, error code is shown on the OUTDOOR UNIT main PBA or LCD of
the wired remote controller.
Display Explanation
101 CONTROL KIT / OUTDOOR UNIT wire connection error
102 CONTROL KIT / OUTDOOR UNIT communication time out error
162 EEPROM Error
201 CONTROL KIT/OUTDOOR UNIT communication error (Matching error)
202 CONTROL KIT/OUTDOOR UNIT communication error (3 min)
203 Communication error between INVERTER and MAIN MICOM (6 min)
221 OUTDOOR UNIT temperature sensor error
231 condenser temperature sensor error
251 Discharge temperature sensor error
320 OLP sensor error
EHS Control unit_MIM-E03@_IM_E_34413-2.indd 34 2012-03-08 오후 5:55:27