8) No Power
Description : When system power is turned on, all lamps on the operator panel do not come on.
1. Check if the power input
and SMPS output are normal.
Replace the power supply cord
or SMPS.
1. Replace the control board.
2. Replace the OP panel.
2. Check the inferiority
RI/('3DQHORU/'&ZLQGRZRQWKH
front-cover if the OP panel does not
appear after normal
warming-up.