English _7
Adjusting the angle in all four directions
Adjust the orientation of the sensor in a desired direction, and use the bottom
screw to fi x it.
Cable Color & Cover Structure
Black: GND
Red: VCC (12V±15%)
Check the polarity of the power cable to ensure
the proper connection.
Green: COM
Blue: OUT (N.C/N.O)
Terminal Panel & PIN Setting
1. GND
2. VCC
3. Alarm (COM)
4. Alarm (N.C/N.O)
5, 6. Tamper
Jumper Pin BU1 BU2 BU3 BU4
Use Count OUT LED Memory
Upper 4 C N.O ON ON
Lower 2 C N.C OFF OFF
J
Left/Right
Up/Down
Alarm Tamper
Memory