English English _ 11
INITIALIZATION
initialization
OUTPUT FORMAT
You can adjust the output format of the numeric values from the keypad.
You can select 4/8 bit Burst or 34bit Wiegand.
Adjust the format according to the controller receiving the keypad input.
To change the output format, use the switch on the rear of the
product.
See the table below to make adjustment as needed.
Output Format
SW #1
SW #2 Output Format of Card Output Format of Keypad
ON ON 34bit Wiegand + RS-232 34bit Wiegand+RS-232
ON OFF 34bit Wiegand + RS-232 34bit Wiegand+RS-232
OFF ON 34bit Wiegand + RS-232 4 bit Burst
OFF OFF 34bit Wiegand + RS-232 8 bit Burst (Default)
All switches are defaulted to “OFF”.
Before you change the output format, you must disconnected the power.
1.
2.
M
ON
12
Vedere la pagina 10