Samsung ASV09PSBAX Manuale Utente

Navigare online o scaricare Manuale Utente per Climatizzatori a split Samsung ASV09PSBAX. Samsung ASV09PSBAX User manual Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa

Sommario

Pagina 1

1AAENGLISHBrazil_AQV&ASV09P@_IBIM_32441A_E.indd 1 2011-6-18 11:10:59

Pagina 2 - Contents

10AABasic operation is an operation mode that can be selected by pressing the Mode button. Basic functionAutoIn Auto mode, the air conditioner will au

Pagina 3

11ENGLISHPress the button to turn on the air conditioner.Press the button to set the operating mode.• EachtimeyoupresstheMode button, the mo

Pagina 4 - AASafety precautions

12AAAdjusting the air ow directionAir ow can be directed to your desired position.Turbo function will be helpful to cool your room quickly and eect

Pagina 5 - FOR CLEANING

13AAENGLISH modeFor a comfortable sleep, the air conditioner will operate it Fall asleep  Sound sleep  Wake up from mode.1. Press the button on

Pagina 6 - Checking before use

14AASetting the On/O timerYou can set the air conditioner to turn on/o automatically at desired time. Setting On timer while the air conditioner is

Pagina 7 - Main parts

15ENGLISHCombining On Timer and O TimerIf the air conditioner is on If the air conditioner is oPreset time on On timer is longer than O timerEx)On

Pagina 8 - Remote controller buttons

16Using the Smart Saver functionThis function will set the temperature range limit to help you save energy while the air conditioner is operating in C

Pagina 9 - Remote controller display

17ENGLISHUsing the SPi functionSPi (Super Plasma ion) generates hydrogen(H) and oxygen(O2) to remove a polluted substance and decomposition of such ha

Pagina 10 - Basic function

18AAUsing the Auto Clean functionAuto clean function will prevent from growing mold by eliminating the moisture inside of the indoor unit. Your indoor

Pagina 11

19AAENGLISHCleaning the air conditionerCleaning the indoor unitCleaning the outdoor unit heat exchangerOpening the panel Wipe the surface of the uni

Pagina 12 - Using the Turbo function

2AASafety precautions ... 3Checking before use ...

Pagina 13 - (Model AQV)

20AACleaning the air conditionerRemoving the Air lterGrab the handle and lift it up. Then, pull the Air lter towards you and slide it down. Cleaning

Pagina 14 - Setting the On/O timer

21AAENGLISHMaintaining the air conditionerIf the air conditioner will not be used for an extended period of time, dry the air conditioner to maintain

Pagina 15

22AATroubleshootingRefer to the following chart if the air conditioner operates abnormally. This may save time and unnecessary expenses.PROBLEM SOLUTI

Pagina 16

23ENGLISHPROBLEM SOLUTIONError is indicated. • When an indoor unit indicator blinks, contact the nearest service center.Noise is generated. • Depe

Pagina 17 - Using the Quiet function

24Carefully follow the precautions listed below because they are essential to guarantee the safety of the equipment.•Alwaysdisconnecttheaircondi

Pagina 18 - Using the Auto Clean function

25ENGLISHInstalling the unitIMPORTANT:Wheninstallingtheunit,alwaysremembertoconnectrsttherefrigeranttubes,thentheelectricallines. A

Pagina 19 - Cleaning the air conditioner

26AAOutdoor Unit Where it is not exposed to strong wind Well ventilated and dustless places Out of the direct sunlight and rainWhere neighbors

Pagina 20

27ENGLISHSpace Requirements for Outdoor UnitWhen installing 1 outdoor unitWhen installing more than 1 outdoor unit300 or more When the air outlet is

Pagina 21 - Periodical checks

28AAChoosing the installation location(Unit:mm) When the upper part of the outdoor unit and the air outlet is opposite the wall When the walls a

Pagina 22 - AATroubleshooting

29ENGLISH• Makesuretodrillonlyoneholeafterchoosingthedirectionofthepipe.Fixing the installation plateThefollowingconnectionaccessori

Pagina 23

3AAENGLISHSafety precautionsBefore using your new air conditioner, please read this manual thoroughly to ensure that you know how to safely and ecien

Pagina 24 - Safety precautions

30AAWall<20mmPlastic AnchorFixing the installation plate2. Fix the indoor unit.If you x the indoor unit on a wall (1) Fix the installation plat

Pagina 25 - Indoor unit

31ENGLISH2 . Open the front grille.3 . Remove the screw securing the connector cover.4 . Pass the assembly cable through the rear of the indoor uni

Pagina 26 - Outdoor Unit

32AAInstalling and connecting the assembly pipe of the indoor unit1. Cut out the appropriate knock-out piece (A, B, C) on the rear of the indoor unit

Pagina 27

33AAENGLISHPurging the indoor unit1. Unscrew the caps at the end of each pipe.   All inert gas exhausts from the indoor unit. 1. Make sure that

Pagina 28 - Accessories

34AACutting or extending the pipeOuter Diameter Torque (kgf•cm)ø6.35 mm 140~170ø9.52 mm 250~280ø12.70 mm 380~420ø15.88 mm 440~480ø19.05 mm 990~1210ø22

Pagina 29 - Fixing the installation plate

35ENGLISH• Thehosewillbexedpermanentlyintopositionafternishingtheinstallationandthegasleaktest;refertopage39-40 for further de

Pagina 30 - Connecting the assembly cable

36AAInstalling and connecting the drain hose of the outdoor unitPurging the connected pipes1. Connect each assembly pipe to the appropriate valve on

Pagina 31

37ENGLISH3. Connect the charging hose of the low-pressure side of manifold gauge to a gas service port as seen in the picture.4. Open the valve of t

Pagina 32

38Purging the connected pipesR410A is a mixed type of refrigerant. It is necessary for recharging under conditions of liquid. When recharging refriger

Pagina 33 - Cutting or extending the pipe

39ENGLISHPerforming the gas leak testsCDABMake sure to check for gas leaks before completing the installation process (connecting the assembly pipe an

Pagina 34 - Flare nut

4AASafety precautionsFOR POWER SUPPLYWARNINGRemove all foreign substances such as dust or water from the power plug terminals and contact points using

Pagina 35 - Drain hose installation

40Fixing the indoor unit in placeInsulationPipesPerform the following work on the area where gas leak test was done priorly.After checking for gas lea

Pagina 36 - Purging the connected pipes

41AAENGLISHFinal Check and Trial Operation1. Turn on the air conditioner and select Cool mode to run the compressor for 3 minutes. 2 . Release the

Pagina 37 - Adding Refrigerant

42AAHow to connect your extended power cables Items to prepare (compressor and insulation tape should be prepared by an installation technician.)1

Pagina 38

43ENGLISHBrazil_AQV&ASV09P@_IBIM_32441A_E.indd 43 2011-6-18 11:11:53

Pagina 39 - Performing the gas leak tests

QUESTIONS OR COMMENTS?COUNTRY CALL OR VISIT US ONLINE AT ARGENTINE 0800-333-3733 www.samsung.comBRAZIL0800-124-421 4004-0000www.samsung.comCHILE 800

Pagina 40

DB98-32441A-1Air Conditioneruser & installation manualimagine the possibilitiesThank you for purchasing this Samsung product. To receive more co

Pagina 41

5ENGLISHFOR USINGWARNINGDo not place an object near the outdoor unit that allows children to climb onto the machine. This may result in children ser

Pagina 42

6AAChecking before useOperation rangesThe table below indicates the temperature and humidity ranges the air conditioner can be operated within. Refer

Pagina 43

7AAENGLISHYour air conditioner may slightly look dierent from illustration shown above depending on your model.Checking the name of the partsMain par

Pagina 44 - QUESTIONS OR COMMENTS?

8AAChecking the remote controllerRemote controller buttons• Pointtheremotecontrollertowardstheremotecontrollerreceiveroftheindoorunit.•

Pagina 45 - Air Conditioner

9ENGLISHRemote controller display• Thesignalmaynotbereceivedwellofelectroniclightingstyleuorescentlampssuchasinverteruorescentlam

Commenti su questo manuale

Nessun commento