INDOOR UNITSH09BPDSH12BPDOUTDOOR UNITSH09BPDXSH12BPDXSERVICEManualCONTENTSAIR CONDITIONER1. Product Specifications2. Operating Instructions 3. Disasse
Disassembly and Reassembly9Samsung ElectronicsNo Parts Procedure Remark23Electrical Parts(Main PCB)Tray Drain10) At first, press the left and center h
Disassembly and ReassemblySamsung Electronics10No Parts Procedure Remark45Heat ExchangerFan Motor&Cross Fan1) Loosen 2 fixing earth screws of righ
11Samsung Electronics3-2 Outdoor UnitNo Parts Procedure Remark1 Common Work&Ass'y-control Out1) Loosen the fixing screw and detach theCover-V
Disassembly and ReassemblySamsung Electronics12No Parts Procedure Remark23Fan-MotorHeat Exchanger1) Loosen 4 fixing screws of the Guard-Fan.2) Remove
Disassembly and Reassembly13Samsung ElectronicsNo Parts Procedure Remark4Compressor1) Open the Terminal Cover of Compressorand unscrew the Connection
Samsung Electronics144. Refrigerating Cycle DiagramIndoor UnitOutdoor UnitT1T22-Way valveEEV3-Way valveGas sideHeatExchanger(Evaporator)HeatExchanger(
15Samsung Electronics5. Set Up the Model Option5-1 Setting Option Setup Methodex) Option No. :Step 1 : Enter the Option Setup mode.1stTake out the bat
Samsung Electronics16Set Up the Model OptionStep 3 : Upon completion of the selection, check you made right selections.Press the Mode Selection key,
17Samsung ElectronicsSet up the Model Option OPTION ITEMSREMOCONMODELSEG1 SEG2 SEG3 SEG4 SEG5 SEG6 SEG7 SEG8 SEG9 SEG10 SEG11 SEG12SH09BPDSH12BPD0090
Samsung Electronics186. Troubleshooting6-1 Basic items for trouble shootingSince the inverter air conditioner is equipped with Electrical control circ
1Samsung Electronics1. Product Specifications1-1 TableModelItemSH12BPDSH12BPDXPower Source ø-V-HzCapacityWBTU/hEnergy Efficiency Ratio BTU/whAir Flow
19Samsung Electronics6-2 The first determination method of troubled part6-2-1 Error mode display of indoor unitIndoor UnitIndoor unit room temperature
TroubleshootingSamsung Electronics20ULN2003ARED GRN YEL6-2-2 Error mode display of outdoor unit boardNormal operation and communication (Indoor _Outdo
21Samsung Electronics6-3 Sequence of trouble shooting for inverter airconOPERATION START• The indoor unit does not work eventhough the power is plugge
TroubleshootingSamsung Electronics226-3-1 (A) Check of indoor unit control board√ Unplug the power cord and plug it after 5 seconds.√ Press the on/off
Troubleshooting23Samsung Electronics6-3-4 (E) Check of indoor unit fan motor 1. √ Check whether the wires are connected surely between control board(C
TroubleshootingSamsung Electronics246-3-7 (H) Check the defrost temperature sensor and outdoor temperature sensor.√ Connector of outdoor unit control
Troubleshooting25Samsung Electronics6-3-11 (L) Check of instantaneous over-current protection of IPM circuit.√ Inverter instantaneous over-current pro
TroubleshootingSamsung Electronics266-3-13 (N) Check of the heatsink temperature abnormal rise√ If the air flow around the heatsink on the control box
27Samsung Electronics6-4 Fault Diagnosis of Major Parts• Indoor "Temp.Sensor"• Indoor "Heat ex. Sensor"• Outdoor "Temp.Sensor
Samsung Electronics28612-412-212-112-512-312-628511-1-21-1-41-1-51-1-61-1-7121-41-31-21-1-11-133-177-57-67-77-47-17-97-87-107-27-3101-1-31194You can s
Samsung Electronics21-2 Pressure Graph SH09BPD76.565.554.5432.430.628.827.024.021.5Outdoor inlet air DB temp.( C)Low Pressure (kg/cm2G)Indoor Inlet a
29Samsung ElectronicsExploded Views and Parts List Parts ListQ'TYNo. Code No. Description Specification RemarkSH09BPD SH12BPD11111111111111111111
Samsung Electronics307-2 Outdoor Unit88-16-178-262121-12011105423119222324181617151214139
31Samsung ElectronicsExploded Views and Parts List Parts ListQ'TYNo. Code No. Description Specification RemarkSH09BPDX SH12BPDX111111111111111133
Samsung Electronics327-3 Ass'y Control In (Indoor Unit) SH09BPD/SH12BPD : DB93-02583A
33Samsung ElectronicsExploded Views and Parts List Parts ListQ'TY RemarkNo. Code No. Description Specification12345678910111213141516171819202122
Samsung Electronics347-4 Ass'y Control Out (Outdoor Unit) SH09BPDX/SH12BPDX : DB93-02582A
Exploded Views and Parts List35Samsung Electronics Parts ListQ'TY RemarkNo. Code No. Description Specification1 DB61-00744A CASE CONTROL BASE RES
Samsung Electronics368. PCB Diagram8-1 ASS'Y PCB Indoor Unit : DB93-02584A TOP
37Samsung ElectronicsPCB Diagram BOTTOM
Samsung Electronics38PCB Diagram Parts ListD101 DIODE-RECTIFIER UG2D,200V,2A,DO-204AC,TP 1D701,D702,D703 DIODE-RECTIFIER MRA4005,600V,1A,SMA,TP 3BD71
3Samsung Electronics2. Operating Instructions2-1 The Feature of Key in remote controlFan speed adjustment button.Each time you press this button, FAN
39Samsung ElectronicsPCB Diagram Parts List (cont.)C301,C510,C706,C903 C-CER,CHIP 1nF,10%,50V,X7R,TP,2012,- 4C203,C204,C302,C303 C-CER,CHIP 10nF,+80-2
Samsung Electronics408-2 ASS'Y PCB Outdoor Unit : DB93-02581A TOP
PCB Diagram41Samsung Electronics Parts ListZD21 DIODE-ZENER AXIAL;1N4749 24V,5% 1W DO-41 TP 1IC55 IC-LOGIC ULN2003ADR,NPN,7,1W,SOP-16,ST,1000 1L701,LE
PCB DiagramSamsung Electronics42 Parts List (cont.)CN13,CN14 CONNECTOR-HEADER BOXZ,2P,1R,2mmSTRAIGHT,SN,WHT 2DSA2 SURGE-ABSORBERPOSISTOR;DAS-332MA,2pF
PCB Diagram43Samsung Electronics Parts List (cont.)IC74 IC-LOGIC 74ALVCOM,14-SOIC 1IC84 IC-TTL DM74ALS1034,14-SOIC 1Q701,Q801 IC-TR BC847B,NPN,SOT-23
PCB DiagramSamsung Electronics44 BOTTOM
PCB Diagram45Samsung Electronics Parts ListR115,R432,R433,R438,R439R440,R520,R521,R522,R523R524,R808,R809,R810,R909R806R504R429,R430,R431,R435,R436R43
PCB DiagramSamsung Electronics46 Parts List (cont.)C401,C402,C403C412,C413,C414C418,C801C467D201IC42R110,R111R412,R427,R428,R434,R441R803R805R901ZD81,
47Samsung Electronics8-3 ASS'Y DISPLAY PCB(9K/12K) : DB93-01368G Parts ListNo1 ASS'Y LED MODULE 1 SNA2 PCB-DISPLAY FR-1 T1.6 1 SNA3 TACT SWI
Samsung Electronics488-4 ASS'Y MODULE PCB(9K/12K) : DB93-01369A Parts ListNo1 PCB-DISPLAY FR-1 T1.6 1 SNA2 CONNECTOR SMAW200-03P(WHT) 1 SNA3 C-CE
Operating InstructionsSamsung Electronics4Digital On/Off button.If you want to turn off the display during operation press the button
49Samsung Electronics9. Wiring Diagram9-1 Indoor Unit(9K/12K)This Document can not be used without Samsung's authorization.Code No : DB98-16258A
Samsung Electronics50This Document can not be used without Samsung's authorization.9-2 Outdoor Unit(9K/12K)Code No : DB98-16257A
MEMO51Samsung Electronics
MEMOSamsung Electronics52
MEMO53Samsung Electronics
MEMOSamsung Electronics54
ELECTRONICSThis Service Manual is a property of Samsung Electronics Co., Ltd.Any unauthorized use of Manual can be punished under applicableInternatio
5Samsung ElectronicsOperating Instructions1. AUTO MODE : In this mode, operation mode(COOL,HEAT) is selected automatically by the room temperatureof
Operating InstructionsSamsung Electronics69. SWING : BLADE-H is rotated vertically by the steppingmotor.*Swing Set : Press the button under the
7Samsung Electronics2-2 Replace PCB Model option2-2-1 Replace PCB model optionNoYesRemove power cordReplace the PCB moduleCheck the connection and plu
Samsung Electronics83. Disassembly and Reassembly3-1 Indoor UnitStop operation of the air conditioner and remove the power cord before repairing the u
Commenti su questo manuale