5 Troubleshooting
LW22A13W 5-9
CONFIDENTIAL
5-5 No Picture (Video_CVBS)
Does the signal appear at R8?
Change s video cable.
Change a input board assy. (BN59-00339A)
Power indicator is off,
Lamp on, No picture.
Yes
Yes
No
Connect the video cable.
Operating a video player.
No
Does the signal appear at
C046(#8) of input IC011?
Change FPC cable. (CN101)
Change a input board assy. (BN59-00339A)
Yes
No
Does the clock pulse appear at
output of IC006~IC009?
IC010 is bad.
Change main board assy. (BN94-00400A)
Yes
No
Does the clock pules appear at
output of IC002~IC005?
IC001 or ICP18 are bad.
Change main board assy. (BN94-00400A)
Yes
No
Does the signal appear at CR01,
CG01, CB01 of R, G, B output?
IC200 is bad.
Change main board assy. (BN94-00400A)
Yes
No
Does the clock pulse appear at
output of RA311~RA313?
IC300 or IC901 are bad.
Change main board assy. (BN94-00400A)
Yes
No
Check a LVDS cable.
Replace a assy LCD panel.
(BN91-00388L)
Please, call to Samsung Co, LTD.