1) Freezer Temperature Shift (Unit ˚C)
SHIFT
Reference
-0.5
-1.0
-2.0
-3.0
+1.0
+2.0
+3.0
D601
-
-
-
-
D602
-
-
-
-
D603
-
-
-
-
2) Refrigerator Temperature Shift (Unit ˚C)
SHIFT
Reference
-0.5
-1.0
-2.0
-3.0
+1.0
+2.0
+3.0
D604
-
-
-
-
D605
-
-
-
-
D606
-
-
-
-
Temperature and function values are changeable by using main PCB switching diode.
Note : If possible, do not change because the values have been set in factory. When changing option
functions, power should be turned off.