INSTALLATION AND EXTERNAL CONNECTION
CABLE SELECTION
Item
Cable TypeCable Type
1
Power (DC12V)
DC Power This Product
Belden #9409, 18 AWG 2 Conductor, Unshielded Belden #9409, 18 AWG 2 Conductor, Unshielded
2
Reader (power and data)
External Reader This Product
Belden #9512, 22 AWG 4 Conductor, Shielded
Belden #9514, 22 AWG 8 Conductor, Shielded
3
Door Contact Sensor
Exit Button
Sensor Input
Input This Product
Belden #9512, 22 AWG 4 Conductor, Shielded
Belden #9514, 22 AWG 8 Conductor, Shielded
4
Door Lock,
Alarm Device
Lock (Alarm) This Product
Belden #9409, 18 AWG 2 Conductor, Unshielded Belden #9409, 18 AWG 2 Conductor, Unshielded
The cables should be thick enough to allow the maximum current consumed by the reader.
J
X Y Z
[ \ ]
^ _ `
lzj lu{
W
i
zzhTzYWWW
DC12V
Power Supply
RF Reader Lock/Alarm
Sensor Input