Samsung SSC-17TQ Manuale di Installazione Pagina 7

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 25
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 6
e-13e-12
6-pin modular jack
Used to connect the camera to the monitor.
<Sensor Detection Angle & Area>
1> Vertical Detection Line
2> Horizontal Detection Area
5-Pin Terminal Block
A terminal block for supplying backup power for the PIR sensor operation during power
outages and for transmitting the relay signals to external devices during the PIR sensor
operation.
5 4 3 2
1
PIN NUMBER
!
@
#
$
%
^
SPEC
SPEAKER(HOT)
VIDEO_OUT
GND
SPEAKER(COLD)
AUDIO_OUT/ALARM_OUT
12V DC
PIN
!
@
#
$
%
SPEC
Power Input DC 12 Volts
(Back Up) Ground
Not Used
Relay Output COM
(350V 130mA) N.C
• Please consider the horizontal detection area and the vertical detection line when choosing
an installation site.