Samsung MIM-B17C Manuale di Servizio Pagina 56

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 202
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 55
56
3
4 way cassette S
X Ratings shown are net capacities.
X Capacities are based on following conditions;
- Equivalent refrigerant piping length : 5m / Level difference : 0m.
;
Note
3-2. Capacity tables
9) RC100ZHXEA + NS1004ZXEA
(1) Cooling
Indoor
Temperature(°C)
Outdoor Temperature (°C, DB)
-15 21 35 43 50
WB DB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
14 20 10.47 8.38 1.63 11.62 9.30 1.86 9.30 7.44 2.06 9.76 7.81 3.40 8.16 6.53 3.87
16 22 10.73 8.59 1.67 11.91 9.53 1.91 9.53 7.62 2.11 10.00 8.00 3.48 8.36 6.69 3.96
18 25 11.00 8.80 1.71 12.20 9.76 1.95 9.76 7.81 2.17 10.25 8.20 3.57 8.56 6.85 4.06
19 27 11.27 9.01 1.75 12.50 10.00 2.00 10.00 8.00 2.22 10.50 8.40 3.66 8.77 7.02 4.16
22 30 11.54 9.23 1.80 12.80 10.24 2.05 10.24 8.19 2.27 10.75 8.60 3.74 8.98 7.19 4.26
24 32 11.81 9.45 1.84 13.11 10.49 2.10 10.49 8.39 2.33 11.01 8.81 3.83 9.20 7.36 4.36
(2) Heating
Indoor
Temperature(°C)
Outdoor Temperature (°C, DB)
-20 -10 7 24
DB TC PI TC PI TC PI TC PI
16 9.70 4.35 13.40 5.38 11.43 2.38 14.75 2.75
18 9.60 4.31 13.26 5.33 11.31 2.36 14.60 2.72
20 9.51 4.27 13.13 5.28 11.20 2.34 14.46 2.69
21 9.41 4.23 13.00 5.22 11.09 2.31 14.31 2.67
22 9.32 4.18 12.87 5.17 10.98 2.29 14.17 2.64
24 9.22 4.14 12.74 5.12 10.87 2.27 14.03 2.61
TC(Total Capacity, kW), SHC(Sensible Heat Capacity, kW), PI(Power Input, kW)
TC(Total Capacity, kW), PI(Power Input, kW)
10) RC125DHXEB + NS1254DXEA
(1) Cooling
Indoor
Temperature(°C)
Outdoor Temperature (°C, DB)
-15 21 35 43 50
WB DB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
14 20
11.63 9.31 2.28 13.26 10.61 3.29 11.62 9.30 3.63 9.65 7.72 3.66 6.97 5.58 3.19
16 22
11.92 9.53 2.34 13.58 10.87 3.37 11.91 9.53 3.72 9.89 7.91 3.75 7.14 5.72 3.27
18 25
12.21 9.77 2.39 13.92 11.13 3.45 12.20 9.76 3.81 10.13 8.10 3.84 7.32 5.86 3.35
19 27
12.51 10.01 2.45 14.26 11.41 3.54 12.50 10.00 3.90 10.38 8.30 3.93 7.50 6.00 3.43
22 30
12.81 10.25 2.51 14.60 11.68 3.62 12.80 10.24 3.99 10.63 8.50 4.03 7.68 6.14 3.52
24 32
13.12 10.50 2.57 14.95 11.96 3.71 13.11 10.49 4.09 10.88 8.71 4.12 7.86 6.29 3.60
(2) Heating
Indoor
Temperature(°C)
Outdoor Temperature (°C, DB)
-20 -10 7 24
DB TC PI TC PI TC PI TC PI
16
11.12 5.16 11.49 5.25 14.28 3.96 17.55 4.40
18
11.01 5.11 11.37 5.19 14.14 3.92 17.37 4.36
20
10.90 5.06 11.26 5.14 14.00 3.88 17.20 4.32
21
10.79 5.01 11.15 5.09 13.86 3.84 17.03 4.27
22
10.68 4.96 11.04 5.04 13.72 3.80 16.86 4.23
24
10.58 4.91 10.93 4.99 13.58 3.76 16.69 4.19
TC(Total Capacity, kW), SHC(Sensible Heat Capacity, kW), PI(Power Input, kW)
TC(Total Capacity, kW), PI(Power Input, kW)
Vedere la pagina 55
1 2 ... 51 52 53 54 55 56 57 58 59 60 61 ... 201 202

Commenti su questo manuale

Nessun commento