77
Circuit Descriptions
12
-4) Door S/W Sensing Circuit
Door Parts Funtion
1 ) F-Room door open is picked up based on the state (5V/0V)of the MICOM No.31 Port.
When the F-Room door opens, it becomes short between the Door S/W 1&2.And Door S/W 3&4 open.
Vcc R401 Door S/W (3&4)open R402(10K) MICOM 31 PORT.
When the state of MICOM 31 PORT is 0.7V, the door is picked up as closed. When it is 5V, the door is considered to be open.
2) R-Room door open is picked up based on the state (5V/0V)of the MICOM No.32 Port.
When the R-Room door opens, it becomes short between the Door S/W 1 &2.And Door S/W 3&4 open.
Vcc R403 Door S/W (3&4)open R404(10K) MICOM 32 PORT.
When the state of MICOM 44 PORT is 0V,the door is picked up as closed. When it is 5V, the door is considered to be open.
3) When door open is detected, the MICOM have the relevant Fan Motor stop and the relevant Room Lamp light up.
Depending on the state of Door Open/Close,there are following operations; Lamp On/Off, Fan Motor On/Off and Door open alarm.
So, check relevant items upon A/S.
- DOOR PARTS FUNTION
Terminal
Operation Volt(state)
Freezer
(No.31)
DOOR OPEN
DOOR CLOSE
5V (HIGH)
0.7V (LOW)
Fridge
(No.32)
DOOR OPEN
DOOR CLOSE
5V (HIGH)
0.7V (LOW)
- SENSOR PARTS FUNTION
Terminal No Remark
F-SENSOR (51)
F-DEF-SENSOR (52)
R-SENSOR (53)
R-DEF-SENSOR (54)
EXT-SENSOR (57)
Micom terminal
voltage may
change
according temp.